WHAT TO PREPARE

Match the loading arrangement to the measurement task

Supply a support/contact sketch with the rated direction, minimum useful load, full-scale load and expected peaks. Ask for the calibration procedure to identify its loading fixture and contact distribution. When the installed joint differs from the bench fixture, agree how an in-place check or system calibration will be used.

  • Separate sensor-only calibration from pin-plus-conditioner or complete readout-system calibration.
  • State loading/unloading points, repetitions and required combined-error evaluation in the test specification.
  • Identify temperature conditions, zero treatment and whether cable/conditioner changes are included.
MT-LPS / DUAL / CONCEPT GEOMETRYLCABDF↑ Y→ XIllustrative section · not a manufacturing or approved lifting drawing
Internally gauged pin · highlighted shear planes · concept only

For X/Y pins, document axes and correction together

A dual-axis brief needs signed X and Y directions, channel ranges, output scaling and a method for evaluating cross-axis response. Vector magnitude and angle must use the same axis convention as the calibration record. A radial magnitude alone can conceal the sign or direction of a channel error.

  • Request a channel identity and angular datum on the approval drawing.
  • Define whether a crosstalk correction matrix is required and where it is applied.
  • Check software calculations using known signed input examples before reading hardware values.

Keep calibration, proof and environmental tests distinct

Calibration describes the measurement response under a specified procedure. A proof-load test addresses an agreed load exposure, while an immersion/pressure test addresses a defined environmental condition. None should be substituted for another in the quote or report. Exact limits and pass criteria must be agreed for the actual pin and assembly.

  • List each requested test and its acceptance criteria separately.
  • Request pin identity, drawing revision, fixture/method and instrument references in the records.
  • Specify whether a third-party or accredited service is required; availability and scope need written confirmation.
Use this review matrix with the actual joint drawing
Item / conditionInformation to confirmDecision boundary
Calibration recordPoints, direction, fixture, zero/span and channel scalingProvides the measurement basis for the stated setup
Proof-load recordLoad, duration, configuration and acceptance methodNot a replacement for calibration or an assembly WLL declaration
Environmental recordDepth/pressure, time, temperature, cycles and connector stateApplies to the tested assembly and conditions

measurement acceptance: questions to resolve

Can I use a factory calibration factor after changing supports?

Describe the change and agree an installed check. Contact distribution and orientation can change the measurement response.

Is a certificate included with every quoted option?

The written quotation must identify which calibration, proof or third-party documents are included. No certificate scope is assumed from a photo or series name.

Original technical references

References describe their manufacturers’ products and methods. They do not establish MT-LPS compatibility, certification or performance. Our diagrams and worked briefs are illustrative; configuration-specific documents govern supply and installation.

Continue your engineering brief

THE FIVE-DIMENSION BRIEF

Your existing pin is the starting point.

Measure D / L / A / B / C or attach a sketch. We review the joint, load cases and interfaces before releasing a drawing or quotation.

MT-LPS / CLEVIS / CONCEPT GEOMETRYLCABDFIllustrative section · not a manufacturing or approved lifting drawing
Axial exit · Keeper slot · labels follow your entries; geometry is schematic
D
Pin diameter and fit
L
Overall loaded length
A
Center loading tongue width
B
Each outer clevis lug width
C
Shear-groove center spacing

L describes the loaded span here. Include the overall end-to-end length, asymmetric lugs, spacers and retention details in your drawing or notes. Five values start the review; they do not fully define a production pin.

Download sizing sheet ↓
Pin configuration and contact details

MT-LPS-2D / ENGINEERING RFQ

01 / Joint dimensions

Changing units converts entered values. Enter tolerances and full end-to-end length in the fit notes below.

02 / Load and environment
03 / Cable exit and pin retention
Axial cable — check clearance
Keeper datum controls rotation
04 / Engineering options

Indicative selected options: +US$0. Base pin, shipping and taxes excluded. Final feasibility and pricing by quotation.

05 / Send for a drawing review
Your engineering brief

MT-LPS-2D · Robotic or Heavy Joint · Standard mV/V bridge

D: — / L: — / A: — / B: — / C: — mm

Axial cable · Keeper slot · option increment +US$0

Requested pin force: To confirm

Complete the brief below for drawing and quotation review.

The local text download contains engineering selections only. Contact fields, project notes and attachment contents are omitted.

Submitting shares your details and attachment for this RFQ under our privacy policy. A one-piece prototype can be requested; tooling fees, STEP drawing timing and dispatch are confirmed in the written quote.

Prefer email? [email protected]